A QUALITATIVE ANALYSIS OF BIOMASS FLOW SENSING BEHAVIOR USING CAPACITIVE TECHNIQUE

Authors

  • Rumana Tasnim Student
  • Sheroz Khan Associate Professor, Department of ECE, , IIUM
  • Musse Mohamud Associate Professor, Department of ECE, IIUM
  • Atika Arshad Student

DOI:

https://doi.org/10.31436/iiumej.v17i1.459

Abstract

Flowsensing technology from today’s application perspective has gained significant research interest over the past few years. Among the existing sensing techniques, electrostatic and capacitive sensing techniques have proven promising although cable capacitance and stray capacitance cause inaccuracy while measuring very small capacitances. The existing measurement circuit model is complicated and has flawed electrode arrangement. By sensing very small capacitive variation, the developed capacitive technique has proven capable of reducing the stray and residual capacitance effect by using an interface sensing circuit based on circular and semicircular shaped electrode and modified capacitive bridge. The proposed interface circuit is simulated via PSPICE for realizing the small capacitive variation with permittivity variation. Hardware implementation is carried out using a flow sensing set up that senses two kinds of biomass flow variation as a change of dielectric permittivity under room conditions. The output voltage has been reproduced as a representative of the flow. Moreover, a comprehensive investigation into experimental data shows an agreeable level of consistency with the simulation results.

KEYWORDS:  electrodes; sensing; capacitance; electrostatic; piping; measurement

Downloads

Download data is not yet available.

Metrics

Metrics Loading ...

References

[1] Heping Cui & John R. Grace (2006). “Pneumatic conveying of biomass particles: a review”, China Particuology, Vol. 4, No.3-4, pp.183-188.

[2] Yan, Y. (1995). “Flow rate measurement of bulk solids in pneumatic pipelines: problems and solutions”. Bulk Solids Handling, Vol. 6, No. 3, pp. 447–56.

[3] Yan, Y. (1996). “Mass flow measurement of bulk solids in pneumatic pipelines”. Measurement Science and Technology, Vol. 7, No.12, pp.1687–706.

[4] Hrach, D., & Fuchs, A. (2008). “Investigation of field electrode geometries in capacitive flow measurement”. IEEE Sensors 2008, pp. 17–20.

[5] Brasseur, G., Brandstatter, B., & Zangl, H. (2003). “State of the Art of Robust Capacitive Sensors”. IEEE Transactions on Instrumentation and Measurement, Vol. 52, No.4, pp. 1261-1265.

[6] Bretterklieber, T., Zangl, H., Hrach, D., Holler, G., Hammerschmidt, D., & Motz, M. (2008). “Versatile Programmable Integrated Interface for Robust Capacitive Sensors”. Elektrotechnik and Information stechnik, Vol. 125, No.4, pp.123-128.

[7] Hu, H.L., Xu, T.M., Hui, S. E., & Zhou, Q.L. (2006). “A novel capacitive system for the concentration measurement of pneumatically conveyed pulverized fuel at power stations”. Flow measurement and Instrumentation, Vol. 17, pp.87-92.

[8] Holler, G., Fuchs, A., & Hrach, D. (2008). “Flow velocity determination in cryogenic media by means of capacitive sensing”. Sensing Technology ICST 2008, pp. 472–476.

[9] Xiangchen Qian & Yong Yan. (2012). “Flow Measurement of Biomass and Blended Biomass Fuels in Pneumatic Conveying Pipelines Using Electrostatic Sensor-Arrays”.IEEE Transactions on Instrumentation and Measurement, Vol. 61, No.5, pp. 1343- 1352.

[10] Bera, S.C., & Mandal, H., (2012). “A Flow Measurement Technique Using a Noncontact Capacitance-Type Orifice Transducer for a Conducting Liquid”. IEEE Transactions on Instrumentation and Measurement, Vol. 61, No. 9, pp.25-53

Downloads

Published

2016-04-30

How to Cite

Tasnim, R., Khan, S., Mohamud, M., & Arshad, A. (2016). A QUALITATIVE ANALYSIS OF BIOMASS FLOW SENSING BEHAVIOR USING CAPACITIVE TECHNIQUE. IIUM Engineering Journal, 17(1), 29–40. https://doi.org/10.31436/iiumej.v17i1.459