Comparison between Point-Based and Ring-Based Technologies in Keratometric Measurement among Post Myopic Laser Refractive Surgery Patients
DOI:
https://doi.org/10.31436/imjm.v16i1.1140Abstract
Introduction: Corneal power or keratometric value represents two-third of total refractive power of the eye. It is an important parameter in intraocular lens calculation. Purpose of the study was to evaluate repeatability and agreement of keratometric measurements obtained from a six points-based keratometry device; IOLMaster 500 (Carl Zeiss Meditec AG, Jena, Germany) and two Placido disc-based keratometry devices; Atlas Topographer 995 and 9000 models (Carl Zeiss Meditec AG, Jena, Germany). Materials and method: A total of 97 post myopic laser refractive surgery subjects were recruited. Three set of mean corneal power measurements from each device were performed by an examiner in a single visit. The repeatability was evaluated by withinsubject standard deviation, coefficient of variation and intraclass correlation coefficient. A one-way repeated measures analysis of variance was conducted to evaluate keratometric measurement differences between the devices. The BlandAltman analysis was employed to assess inter-device agreement. Results: There were no significant differences of three repeated keratometric measurements in each device (p > 0.05). IOLMaster showed the lowest coefficient of variations in all meridians (< 0.30%).The intraclass correlations were higher than 0.90 in all devices. For inter-device agreement, there were statistically significant differences between Atlas 9000-IOLMaster and Atlas 995-IOLMaster (p < 0.05). The 95% limit of agreement ranged from 0.94 to 1.68. Conclusion: The six points-based technology has a higher repeatability compared to ring based technology in measuring postoperative keratometric measurements. Different keratometry technologies cannot be used interchangeably in clinical setting.
Downloads
Downloads
Published
How to Cite
Issue
Section
License
All material submitted for publication is assumed to be submitted exclusively to the IIUM Medical Journal Malaysia (IMJM) unless the contrary is stated. Manuscript decisions are based on a double-blinded peer review process. The Editor retains the right to determine the style and if necessary, edit and shorten any material accepted for publication.
IMJM retain copyright to all the articles published in the journal. All final ‘proof’ submissions must be accompanied by a completed Copyright Assignment Form, duly signed by all authors. The author(s) or copyright owner(s) irrevocably grant(s) to any third party, in advance and in perpetuity, the right to use, reproduce or disseminate the research article in its entirety or in part, in any format or medium, provided that no substantive errors are introduced in the process, proper attribution of authorship and correct citation details are given, and that the bibliographic details are not changed. If the article is reproduced or disseminated in part, this must be clearly and unequivocally indicated.