Does Mesh Augmentation of the Hiatal Repair with Gore Bio-A® Improve Symptomatic Outcomes in Laparoscopic Fundoplication?
DOI:
https://doi.org/10.31436/imjm.v14i1.455Abstract
Introduction: Laparoscopic fundoplication is performed for the management of symptomatic hiatus hernias and gastro-oesophageal reflux disease (GORD) refractory to medical therapy. We adopted the use of Gore Bio-A® for selected laparoscopic hiatus hernia repairs in 2011 and with this case series aimed to establish whether mesh augmentation affects symptomatic outcomes. Methods: A retrospective review of prospectively collected data from all laparoscopic fundoplications performed by a single surgeon between October 2011 and January 2013 was performed. Patient specific data were entered into a proforma and analysed using Microsoft ExcelTM. Patient reported outcomes were assessed with a system specific quality of life questionnaire (GORD-HRQL) both pre and post-operatively. Results: Twenty-three patients underwent laparoscopic fundoplication during the study period. Gore Bio-A® re-enforcement of the hiatal repair was used in 14 patients and was the preferred option for those with pre-operative evidence of a large hiatus hernia. Whilst overall there was a statistically significant difference between pre and post-operative scores (21 vs 0, p=<0.0001, Mann-Whitney U test), there was no clear difference observed in pre-operative scores (22 vs 20, p=0.21, Mann-Whitney U test), postoperative scores (0 vs 0, p=0.92, Mann-Whitney U test) or symptom improvement (21 vs 20, p=0.24, MannWhitney U test) between the mesh and non-mesh groups. Conclusions: Augmentation of the hiatal repair with biosynthetic mesh is safe, feasible and may contribute to improved symptomatic outcomes in selected cases with a large hiatus hernia. We suggest a further assessment with a larger randomised sample and long term follow-up for definitive evaluation.
Downloads
Downloads
Published
How to Cite
Issue
Section
License
All material submitted for publication is assumed to be submitted exclusively to the IIUM Medical Journal Malaysia (IMJM) unless the contrary is stated. Manuscript decisions are based on a double-blinded peer review process. The Editor retains the right to determine the style and if necessary, edit and shorten any material accepted for publication.
IMJM retain copyright to all the articles published in the journal. All final ‘proof’ submissions must be accompanied by a completed Copyright Assignment Form, duly signed by all authors. The author(s) or copyright owner(s) irrevocably grant(s) to any third party, in advance and in perpetuity, the right to use, reproduce or disseminate the research article in its entirety or in part, in any format or medium, provided that no substantive errors are introduced in the process, proper attribution of authorship and correct citation details are given, and that the bibliographic details are not changed. If the article is reproduced or disseminated in part, this must be clearly and unequivocally indicated.